ABB CRB 1300 Product Manual page 225

Hide thumbs Also See for CRB 1300:
Table of Contents

Advertisement

3
Disconnecting the SMB connectors
1
2
3
Product manual - CRB 1300
3HAC083111-001 Revision: B
Action
Remove the cable brackets from the swing first
and then from the cable package.
Action
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
ELECTROSTATIC DISCHARGE (ESD)
The unit is sensitive to ESD. Before handling the
unit read the safety information in section
unit is sensitive to ESD on page
Remove the SMB cover attachment screws and
carefully open the cover.
CAUTION
Clean cover from metal residues before opening.
Metal residues can cause shortage on the boards
which can result in hazardous failures.
CAUTION
There are cabling attached to the cover. The
cover cannot be removed completely until the
connectors are removed.
© Copyright 2022-2023 ABB. All rights reserved.
5.3.1 Replacing the cable package
Note
xx2000001557
xx2100001466
Note
The
49.
xx2000001503
5 Repair
Continued
Continues on next page
225

Advertisement

Table of Contents
loading