ABB CRB 1300 Product Manual page 455

Hide thumbs Also See for CRB 1300:
Table of Contents

Advertisement

6
Securing the cable package in the lower arm
1
2
Product manual - CRB 1300
3HAC083111-001 Revision: B
Action
Remove the tool and refit the plug screw.
Action
Check the axis-3 cable protector.
Replace if damaged.
Note
If replaced, apply grease to the axis-3 cable pro-
tector before refitting.
Route the cable package through the lower arm
support and up into the housing.
CAUTION
Make sure that no cables or hoses are twisted or
strained. Reroute if necessary.
© Copyright 2022-2023 ABB. All rights reserved.
5.5.3 Replacing the tubular and tilt unit
Note
Tightening torque: 3 Nm
Plug screw: 3HAC078352-001
xx2000001609
Note
Grease: 3HAC029132-001
Plastic cable protector, axis 3:
3HAC064693-001
xx2000001568
Screw: M4x10 12.9 Lafre
2C2B/FC6.9 (3 pcs)
Tightening torque: 2.6 Nm
xx2000001552
Continues on next page
5 Repair
Continued
455

Advertisement

Table of Contents
loading

Table of Contents