Pulling out the cable package
1
2
3
4
5
Refitting the cable package
Use these procedures to refit the cable package.
Securing the cable package in the base
1
Product manual - CRB 1300
3HAC083111-001 Revision: B
Action
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
Remove the axis-1 connector plate.
Wrap the connectors with the masking tape.
Pull out the cable package in the direction as
shown in the figure.
Note
Slip out the cable protectors while pulling out the
cable package.
Slip out the cable protectors.
Action
Wrap the connectors with the masking tape.