ABB CRB 1300 Product Manual page 221

Hide thumbs Also See for CRB 1300:
Table of Contents

Advertisement

2
Disconnecting the axis-4 motor connectors
1
2
3
4
Product manual - CRB 1300
3HAC083111-001 Revision: B
Action
Remove the lamp unit.
Action
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
Remove the connector plate.
CAUTION
Be aware of the cablings that are attached to the
connector plate! The connector plate cannot be
removed completely until the connectors are re-
move from the plate.
Cut the cable strap.
Note
The motor cablings have another strap fixed. Al-
ways cut the strap that fixes the cable package
to the plate.
Disconnect the connectors.
MP4
FB4
Tip
Take photos of the connector and cable position
before disconnecting them, to have as a reference
when reconnecting.
© Copyright 2022-2023 ABB. All rights reserved.
5.3.1 Replacing the cable package
Note
xx2200001003
Note
xx2000001542
xx2000001543
xx2000001544
Continues on next page
5 Repair
Continued
221

Advertisement

Table of Contents
loading

Table of Contents