4
Securing the cable package in the tubular
1
2
Product manual - CRB 1300
3HAC083111-001 Revision: B
Action
Route and secure the cabling with cable straps.
CAUTION
Correct cable routing is highly important.
If the cables are routed and secured incorrectly
the cables can be damaged.
Refit the process hub.
Action
Refit the first semicircular bracket to fix the cable
package.
Refit the connector plate.
© Copyright 2022-2023 ABB. All rights reserved.
5.7.3 Replacing the axis-3 gearbox
Note
Screw: M4x8 12.9 Lafre
2C2B/FC6.9 (4 pcs)
Tightening torque: 2.6 Nm
xx2200001000
Note
Screw: M4x12 12.9 Lafre
2C2B/FC6.9 (2 pcs)
Tightening torque: 2.6 Nm
xx2000001748
Screw: M3x8 12.9 Lafre
2C2B/FC6.9 (2 pcs for each plate)
Tightening torque: 1.3 Nm
xx2000001531