Loosening the cables in the tubular
1
2
3
Disconnecting the axis-6 motor connectors
1
2
Product manual - CRB 1300
3HAC083111-001 Revision: B
Action
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
Cut the cable straps.
Remove the connector plates.
CAUTION
Be aware of the cablings that are attached to the
connector plate! The connector plate cannot be
removed completely until the connectors are re-
move from the plate.
Action
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
Disconnect the connectors.
•
MP6
•
FB6
Tip
Take photos of the connector and cable position
before disconnecting them, to have as a reference
when reconnecting.
© Copyright 2022-2023 ABB. All rights reserved.
5.5.3 Replacing the tubular and tilt unit
Note
xx2000001530
xx2000001531
Note
xx2000001532
Continues on next page
5 Repair
Continued
439