ABB CRB 1300 Product Manual page 583

Hide thumbs Also See for CRB 1300:
Table of Contents

Advertisement

5
6
7
8
9
Product manual - CRB 1300
3HAC083111-001 Revision: B
Action
For robots with protection class IP67 (option
3350-670)
Place the ring of the axis-2 sealing assembly tool
against the sealing.
xx2000002562
Fit the small circular plate of the axis-2 sealing
assembly tool and fix with three M6x75 screws.
Screw the screws, little by little and evenly, to
press the sealing into place.
Remove the assembly tool.
Check that the sealing is undamaged and properly
fitted.
© Copyright 2022-2023 ABB. All rights reserved.
5.7.2 Replacing the axis-2 gearbox
Note
Ring of the axis-2 sealing assembly
tool, included in Special toolkit for
IP67 robots (3HAC078203-001).
xx2000002469
Small circular plate of the axis-2
sealing assembly tool, included in
Special toolkit for IP67 robots
(3HAC078203-001).
xx2000002470
xx2000002471
Continues on next page