5 Repair
5.5.3 Replacing the tubular and tilt unit
Continued
Refitting the lamp unit
Notice that the procedure is valid only when the lamp unit needs a replacement.
1
2
3
Continues on next page
472
Action
Refit the lamp unit.
For robots with protection class IP67 (option
3350-670)
Check the gasket.
Replace if damaged.
Refit the lamp unit cover.
© Copyright 2022-2023 ABB. All rights reserved.
Note
Multi-color lamp unit (16 mm):
3HAC081993-004
xx2200001003
Gasket for lamp unit cover:
3HAC082935-001
xx2200001004
Lamp unit cover: 3HAC082320-001
Screw: M3x8 12.9 Lafre
2C2B/FC6.9 (4 pcs)
Tightening torque: 0.6 Nm
xx2200001002
Product manual - CRB 1300
3HAC083111-001 Revision: B