3 Installation and commissioning
3.7.5.6 Configuration of two SafetyIO-base laser scanners (RobotWare 7.6 or later)
Continued
Configuring SafeMove
To enable SafeMove, perform the following procedure:
154
1 Log in the FlexPendant.
Make sure the user logged in have access grants to lock safety controller
configurations, safety services and software synchronization.
2 Tap SafeMove on the home page.
3 Tap Load in the pop-up message box to confirm loading of template SafeMove
configuration files.
The controller restarts.
4 After the controller is restarted, tap Settings on the home page.
5 Tap Safety Controller.
6 Tap Synchronization in the left pane.
7 Jog the robot to match the Actual Positions values with the Sync Positions
values.
Make sure the values are the same.
8 Tap Synchronize.
© Copyright 2022-2023 ABB. All rights reserved.
Product manual - CRB 1300
3HAC083111-001 Revision: B