Table 115: Ccc Family Configuration Details - Juniper NETWORK AND SECURITY MANAGER 2010.4 - M-SERIES AND MX-SERIES DEVICES GUIDE REV 1 Manual

Network and security manager
Table of Contents

Advertisement

M-series and MX-series Devices
218
In the NSM navigation tree, select Device Manager > Devices.
1.
Click the Device Tree tab, and then double-click the device to select it.
2.
Click the Configuration tab. In the configuration tree, expand Interfaces.
3.
Select Interface.
4.
Add or modify settings as specified in Table 115 on page 218.
5.
Click one:
6.
OK—Saves the changes.
Cancel—Cancels the modifications.

Table 115: Ccc Family Configuration Details

Task
Apply a filter to an interface.
Configure input filter.
Configure output filter.
Your Action
1.
Click Add Interface next to Interface.
2. In the Add Interface Dialog box, enter the interface name.
3. Click Unit next to interface.
4. Click Add new entry next to Unit.
5. Click Family next to Unit.
6. Expand Family.
7. Click Ccc next to Family.
8. In the Comment box, enter the comment.
9. Click Filter next to Ccc.
10. In the Comment box, enter the comment.
11. From the Group list, select the filter group number.
Range: 0 through 255
1.
Click Input next to Filter.
2. Select one of the following:
—To configure name of one filter to evaluate when
Input
packets are received on the interface. Enter the input filter
name.
—To apply a group of filters to evaluate when
Input-list
packets are received on an interface.
a. Click Add new entry next to input-list.
b. In the New input-list window, enter the filter names. Up
to 16 filters can be included in a filter input list.
1.
Click Output next to Filter.
2. Select one of the following:
output—To configure name of one filter to evaluate when
packets are transmitted on the interface. Enter the output
filter name.
output-list — To apply a group of filters to evaluate when
packets are transmitted on an interface.
a. Click Add new entry next to output-list.
b. In the New output-list window, enter the filter names. Up
to 16 filters can be included in a filter input list.
Copyright © 2010, Juniper Networks, Inc.