Table 269: Traceoption BSG Configuration Details (continued)
Task
Configure trace options for
the BSG component that
provides an infrastructure
that enables incremental
functionality
implementation.
Configure trace options for
the Signaling Border
Controller (SBC) utilities
component of the BSG.
Your Action
1.
Click Add new entry next to Gateway.
2. Click Traceoptions next to gateway.
3. Click Flag next to Traceoptions.
4. Click Framework next to Flag.
5. In the Comment box, enter the comment.
6. From the Minimum list, select the minimum trace level for all
framework messages.
7. From the Executor list, select the trace level for the framework
subcomponent that executes configured actions for an event,
handles any error states, delays processing, and so on.
8. From the Action list, select the trace level for the framework
subcomponent that creates, initiates, and manipulates event
actions.
9. From the Event list, select the trace level for the framework
subcomponent that creates, modifies, and terminates event
members.
10. From the Freezer list, select the trace level for the framework
subcomponent that delays the execution of an event until
certain conditions are met.
11. From the Memory Pool list, select the trace level for the
framework subcomponent that creates, deletes, and
manipulates memory pools and pool managers, and controls
the check-in to and check-out from memory pools of memory
objects.
1.
Click Add new entry next to Gateway.
2. Click Traceoptions next to gateway.
3. Click Flag next to Traceoptions.
4. Click Sbc Utils next to Flag.
5. In the Comment box, enter the comment.
6. From the Minimum list, select the minimum trace level for all
sbc-util messages.
7. From the Configuration list, select the trace level for the
configuration component of SBC utilities.
8. From the Ipc list, select the trace level for the IPC component
of SBC utilities.
9. From the Device Monitor list, select the trace level for the
device monitor component of SBC utilities.
10. From the Memory Management list, select the trace level for
the memory management component of SBC utilities.
11. From the Message list, select the trace level for the message
component of SBC utilities.
12. From the Common list, select the trace level for the common
component of SBC utilities.
13. From the User Interface list, select the trace level for the user
interface component of SBC utilities.
14. From the Memory Pool list, select the trace level for the
message component of SBC utilities.
15. From the Memory Pool list, select the trace level for the
memory pool component of SBC utilities.