M-series and MX-series Devices
262
Table 137: Neighbor Interface Configuration Details (continued)
Task
Configure pseudowire
redundancy for Layer 2
circuits and Virtual Private
LAN Service (VPLS).
Specify bandwidth
allocation for a Layer 2
circuit or for the class types
of a Layer 2 circuit.
Configure static Layer 2
circuit pseudowires.
Your Action
1.
Click Interface next to neighbor.
2. Click Add new entry next to Interface.
3. Click Backup Neighbor next to interface.
4. Click Add new entry next to Backup Neighbor.
5. In the Name box, enter the interface name.
6. In the Comment box, enter the comment.
7. From the Virtual Circuit Id list, select the identifier.
Range: 1 through 4,294,967,295
8. In the Community box, specify the community for the Layer 2
circuit.
9. In the Psn Tunnel Endpoint box, enter the address for the
tunnel endpoint.
10. Select the Standby check box to configure the pseudowire to
the specified backup neighbor as the standby.
11. Click Static next to backup-neighbor.
12. In the Comment box, enter the comment.
13. From the Incoming Label list, select the incoming label for the
static pseudowire.
Range: 1000000 through 1048575
14. From the Outgoing Label list, select the outgoing label for the
static pseudowire.
Range: 299776 through 1048575
1.
Click Interface next to neighbor.
2. Click Add new entry next to Interface.
3. Click Bandwidth next to interface.
4. In the Comment box, enter the comment.
5. In the Per Traffic Class Bandwidth box, enter the bandwidth
in bits per second for a class type on the Layer 2 circuit.
6. In the Ctnumber box, enter the bandwidth in bits per second
for a class type on the Layer 2 circuit.
You can configure bandwidth for up to 4 class types (ct0, ct1,
ct2, ct3) per Layer 2 circuit. If you configure the class types,
you must configure them in order, starting with class type ct0.
1.
Click Interface next to neighbor.
2. Click Add new entry next to Interface.
3. Click Static next to interface.
4. In the Comment box, enter the comment.
5. From the Incoming Label list, select the incoming label for the
static pseudowire.
Range: 1000000 through 1048575
6. From the Outgoing Label list, select the outgoing label for the
static pseudowire.
Range: 299776 through 1048575
7. Select the Send Oam check box to send oam.
Copyright © 2010, Juniper Networks, Inc.