Configuring H248 Properties (Nsm Procedure); Table 282: Virtual Interface Indications Configuration Details - Juniper NETWORK AND SECURITY MANAGER 2010.4 - M-SERIES AND MX-SERIES DEVICES GUIDE REV 1 Manual

Network and security manager
Table of Contents

Advertisement

M-series and MX-series Devices

Configuring H248 Properties (NSM Procedure)

474

Table 282: Virtual Interface Indications Configuration Details

Task
Specify the method and
reason that the virtual BGF
includes in ServiceChange
commands that it sends to
the gateway controller when
the state of the virtual
interface changes to
Out-of-Service.
Specifying the
ServiceChange command
that the virtual BGF sends
to the gateway controller
when the state of the virtual
interface changes to
In-Service.
You can configure default values for H248 properties using the following options. See
the following topics:
Configuring Application Data Inactivity Detection (NSM Procedure) on page 475
Configuring Base Root (NSM Procedure) on page 475
Your Action
1.
Click Add new entry next to Gateway.
2. Click H248 Options next to gateway.
3. Expand H248 Options.
4. Click Service Change next to H248 Options.
5. Expand Service Change.
6. Click Virtual Interface Indications next to Service Change.
7. In the Comment box, enter the comment.
8. Expand Virtual Interface Indications.
9. Click Virtual Interface Down next to Virtual Interface
Indications.
10. In the Comment box, enter the comment.
11. From the Graceful list, select the method and reason that the
virtual BGF includes in Notification ServiceChange commands
that it sends to the gateway controller when the control
association transitions from In-Service to
Out-of-Service-Graceful.
12. From the Administrative list, select the method and reason
that the virtual BGF includes in Unregistration Messages in
ServiceChange commands that it sends to the gateway
controller when a control association transitions to
Out-of-Service because of an administrative operation.
13. From the Failure list, select the method and reason that the
virtual BGF includes in Unregistration or Notification Messages
in ServiceChange commands when a control association
transitions to Out-of-Service.
14. From the Link Loss list, select the method and reason that the
virtual BGF includes in Service-Interruption ServiceChange
commands that it sends to the gateway controller when the
virtual interface transitions to Out-of-Service because of a link
loss.
1.
Click Virtual Interface Up next to Virtual Interface Indications.
2. In the Comment box, enter the comment.
3. From the Warm list, select the method and reason that the
virtual BGF includes in Service-Restoration ServiceChange
commands that it sends to the gateway controller when a
virtual interface transitions to In-Service.
4. From the Cancel Graceful list, select the method and reason
that the virtual BGF includes in Notification ServiceChange
commands that it sends to the gateway controller when the
control association transitions from the Draining state to the
Forwarding state.
Copyright © 2010, Juniper Networks, Inc.