Configuring The Neighbor Interface For The Layer 2 Circuit; Procedure); Table 136: Local Switching Configuration Details - Juniper NETWORK AND SECURITY MANAGER 2010.4 - M-SERIES AND MX-SERIES DEVICES GUIDE REV 1 Manual

Network and security manager
Table of Contents

Advertisement

M-series and MX-series Devices
Configuring the Neighbor Interface for the Layer 2 Circuit (NSM Procedure)
260
In the NSM navigation tree, select Device Manager > Devices.
1.
Click the Device Tree tab, and then double-click the device to select it.
2.
Click the Configuration tab. In the configuration tree, expand Protocols > L2 Circuit.
3.
Select Local Switching.
4.
Add or modify settings as specified in Table 136 on page 260.
5.
Click one:
6.
OK—Saves the changes.
Cancel—Cancels the modifications.

Table 136: Local Switching Configuration Details

Task
Configure a local switching
interface.
Configure the interface over
which Layer 2 circuit traffic
travels.
Specify the end interface for
a local interface switch.
Each Layer 2 circuit is represented by the logical interface connecting the local provider
edge (PE) router to the local customer edge (CE) router. All the Layer 2 circuits using a
particular remote PE router designated for remote CE routers are listed under the neighbor
statement (neighbor designates the PE router). Each neighbor is identified by its IP
address and is usually the end-point destination for the Label Switched Path (LSP)
tunnel (transporting the Layer 2 circuit).
To configure a neighbor interface in NSM:
In the NSM navigation tree, select Device Manager > Devices.
1.
Click the Device Tree tab, and then double-click the device to select it.
2.
Your Action
1.
In the Comment box, enter the comment.
1.
Click Interface next to Local Switching.
2. Click Add new entry next to Interface.
3. In the Name box, enter the name of the interface to be
configured.
4. In the Protect Interface box, enter the name of the protect
interface to be configured.
5. In the Description box, enter the text description for the Layer
2 circuit. If the text includes one or more spaces, enclose the
entire text string in quotation marks (" ").
6. Select the Ignore Mtu Mismatch check box to ignore the MTU
configuration set for the physical interface associated with
the local switching interface or with the remote Provider Edge
(PE) router.
1.
Click End Interface next to interface.
2. In the Comment box, enter the comment.
3. In the Interface box, enter the name of the interface.
4. In the Protect Interface box, enter the name of the protect
interface to be configured.