Maintenance-Object Repair Procedures
Table 8-454. Test #61 MET Line Station Audits Test
Error
Test
Code
Result
Description / Recommendation
ABORT
Internal system error
1
ABORT
The test was aborted due to an internal system error during the switchhook
audit.
2
The test was aborted due to an internal system error during the bad scan
inquiry.
3
The test was aborted due to an internal system error during the EPF audit
inquiry.
1. Make sure that the station is not in an out-of-service state.
2. Retry the command at 1-minute intervals up to 5 times.
1000
ABORT
System resources required to run this test are not available. The port may be
busy with a valid call.
1. Use the display port UUCSSpp command to determine the station
2. If the port status is idle, then retry the command at 1-minute intervals up to
1004
ABORT
The port was seized by a valid call during the test. The test has been aborted.
1. Use the display port UUCSSpp command to determine the station
2. Retry the command at 1-minute intervals up to 5 times.
2000
ABORT
Response to the test request was not received within the allowable time period.
1. Retry the command at 1-minute intervals up to 5 times.
FAIL
The test failed due to an internal system error.
1. Retry the command at 1-minute intervals up to 5 times.
8-1106
Issue 1 May 2002
extension of the port. Use the status station command to determine the
service state of the port. If the port is in use, wait until the port is idle
before testing.
5 times.
extension of the port. Use the status station command to determine the
service state of the port. If the port is in use, wait until the port is idle
before testing.