Making Connections To The Slc Connectreach System - Lucent Technologies SLC ConnectReach User & Service Manual

Access system
Table of Contents

Advertisement

®
Configuring the SLC
ConnectReach
®
Preparing the SLC
ConnectReach
Configuration
Making Connections to the SLC
ConnectReach System
There are four ways to obtain initial access to the SLC ConnectReach system in
Introduction
order to perform configuration procedures:
System
System for Initial
Connect a computer directly to the RS-232 port on the SLC ConnectReach
3
system using a null modem cable.
Connect a modem to the RS-232 port on the SLC ConnectReach system
3
using a standard serial cable and then dial up that modem from a remote
computer.
The default settings to use for the connection at the RS-232 port are as
follows:
— 9,600 baud
— Eight data bits
— One stop bit
— No parity
— Hardware flow control.
Connect a computer, running the CTRM terminal emulator software, or an
3
American standard code for information interchange (ASCII) terminal to the
CIT connector on the SLC-2000 RT/HDT UIP and access the SLC
ConnectReach system by means of the T1 network interface. This
arrangement requires Software Release 3.0.5 (R3.0.5) or later for the SLC
ConnectReach system and R4.7 or later for the SLC-2000 RT/HDT.
The default settings to use for the CIT are as follows:
— Full duplex
— Eight data bits
— One start bit
— One stop bit
— No flow control
— Baud rate set the same as the SET-BAUD UIP command.
363-208-050
(Continued on next page)
4-5