Lucent Technologies SLC ConnectReach User & Service Manual page 59

Access system
Table of Contents

Advertisement

Product Description
Physical and Functional Description
Description of Indicators (Continued)
T1 STATUS LEDs
FRAMING LEDs
These two yellow LEDs provide an indication of a yellow alert or bipolar violations
on the network and/or secondary T1/DSX-1 line. The various states of the T1
STATUS LEDs and their indication are as follows:
On — A yellow alert has occurred in the last second.
3
Flashing — One or more bipolar violations has occurred in the last
3
second.
Off — The SLC ConnectReach system is operating normally.
3
NOTE:
The T1 STATUS LED for the secondary T1/DSX-1 line will operate only if
the secondary T1/DSX-1 line is installed and enabled.
These two red LEDs provide an indication of a red alarm condition or a high bit
error rate on the network and/or secondary T1/DSX-1 line. The various states of
the FRAMING LEDs and their indication are as follows:
On — A red alarm condition is present.
3
Flashing — The framing bit error rate has exceeded 10E
3
second.
Off — The SLC ConnectReach system is operating normally.
3
NOTE:
The FRAMING LED for the secondary T1/DSX-1 line will operate only if the
secondary T1/DSX-1 line is installed and enabled.
363-208-050
5
in the last
Issue 4
June 2002
2-17