Lucent Technologies SLC ConnectReach User & Service Manual page 123

Access system
Table of Contents

Advertisement

®
Configuring the SLC
ConnectReach
Using the Configuration Commands
Configuring DS0 Provisioning
(Continued)
Examples of
channel assignment
schemes (continued)
System
When the ConnectReach command is selected, the following is a sample of the
display that will appear on the terminal monitor:
1 - 4
: 440
5 - 8
: 440
9 -12
: 456
13 -16
: none
17- 20
: none
21 -24
: 452
ClearReach-enable
: on
Help
!
The left column in the display indicates a DS0 channel range. The middle column
shows the currently configured channel unit. The right column shows all possible
channel unit choices, including none, with the default choice in square brackets. In
this specific example, for DS0 channels 1 through 4 and 5 through 8,
®
SPQ
440(C,D) channel units are being emulated. An SPQ456 channel unit is
emulated for DS0 channels 9 through 12 and an SPQ452 channel unit is
emulated for DS0 channels 21 through 24. Since DS0 channels 13 through 16
and 17 through 20 have the "none" option, no channel unit is to be emulated in
these positions.
The SPQ400 may only be provisioned in a SLC ConnectReach system operating
as a secondary voice channel, and cannot provide the ClearReach feature.
To change channel unit assignments for a specific DS0 channel range, enter the
following command:
(config:DS0-provisioning:ConnectReach)> channel range channel unit
Example:
(config:DS0-provisioning:ConnectReach)> 1-4 443
([440] 443 452 456 400 none)
([440] 443 452 456 400 none)
([440] 443 452 456 400 none)
([440] 443 452 456 400 none)
([440] 443 452 456 400 none)
([440] 443 452 456 400 none)
(off [on])
(Continued on next page)
Issue 4
June 2002
363-208-050
4-37