Lucent Technologies SLC ConnectReach User & Service Manual page 121

Access system
Table of Contents

Advertisement

®
Configuring the SLC
ConnectReach
Using the Configuration Commands
Configuring DS0 Provisioning
(Continued)
Procedure
(continued)
System
Step
Procedure
3
Assign available channel units to designated DS0 channels and, if
necessary, enable/disable the ClearReach feature using the
ConnectReach command.
NOTE:
Provisioning of the SLC ConnectReach system channel units is
defaulted according to the hardware configuration of the system
(FXS and FXO cards). If an SPQ
®
E SPOTS
using the ConnectReach command.
NOTE:
The ConnectReach command must be executed before saving
other DS0 provisioning values or a confirmation error message may
be displayed.
4
When you have made the necessary configuration changes, you can
return to the Config menu by typing exit or an exclamation point (!)
(quoted as "\ |" through the SLC-2000 Access System CIT).
NOTE:
If you change the begin channel in any of the ranges while using
any of the DS0 commands, the new command values do not take
effect until you save the configuration and reboot the SLC
ConnectReach system using the cold-start command. If you
do not change the begin channel in any of the ranges, the new
command values take effect as soon as you save the configuration.
In this case you do not need to reboot the SLC ConnectReach
system to use the new values.
Stop! End of Procedure.
®
452 data channel unit or SPQ443
channel unit is to be used, then it must be provisioned
363-208-050
(Continued on next page)
Issue 4
June 2002
4-35