Lucent Technologies SLC ConnectReach User & Service Manual page 109

Access system
Table of Contents

Advertisement

®
Configuring the SLC
ConnectReach
Using the Configuration Commands
Configuring the Network T1/DSX-1
Interface (Continued)
Key commands
(continued)
System
Line Buildout
T1 line buildout is configurable to 0 dB, –7.5 dB, or
–15 dB, as required by Federal Communications
Commission (FCC) Part 68. Buildout sets the SLC
ConnectReach system's output T1 transmission signal
level (0 dB is the highest level and –22.5 dB is the
lowest level). The default, 0 dB, is the most common
signal level for connection to the carrier. If line buildout
is set incorrectly, the carrier may detect errors ranging
from bipolar violations (line buildout too high) to loss of
signal (line buildout too low).
Clock Source
Always select network.
Pulse Density
Enforcement
Always set to off.
Alarm Operation
This option controls whether the network T1/DSX-1
going down causes the alarm relay to close. Refer to
Chapter 9, "Software Upgrade, Maintenance, and
Trouble Clearing", for more information.
Alarm Delay
This option sets the delay between when the T1 alarm
is cleared and the relay returns to an unalarmed state.
For example, if the delay is set for 15 seconds, the
alarm relay will go from alarm to no alarm 15 seconds
after the T1 alarm clears.
Is Slave
This option designates one of the two ConnectReach
systems in a 48-line master/slave configuration as the
slave unit. Refer to Chapter 5, "Installation" for details
on the 48-line master/slave configuration.
363-208-050
(Continued on next page)
Issue 4
June 2002
4-23