Lucent Technologies SLC ConnectReach User & Service Manual page 196

Access system
Table of Contents

Advertisement

®
Configuring the SLC
ConnectReach
Using the Configuration Commands
Configuring the SNMP Service
Procedure
4-110
Issue 4
June 2002
System
Step
Procedure
1
At the Config prompt, enter the SNMP command:
(config)> snmp
The prompt changes to the Config:SNMP prompt.
(config:SNMP)>
2
At the Config:SNMP prompt, enter the appropriate commands and options to
configure SNMP from the following table.
Enter this
command...
enable
snmp-host
cold-start
warm-start
link-down
link-up
login-
failures
t1-traps
Help
...and specify
this value
Comments
Enables SNMP.
[off], on
IP address of the SNMP host that will
receive SNMP traps.
IP-address
This trap is sent when the unit has been
powered on, has had a power failure, or has
been rebooted with the cold-start
command.
[off], on
This trap is sent when the unit has detected
a failure and has rebooted (preserving voice
traffic), or has been rebooted with the
warm-start command.
[off], on
This trap is sent when the Ethernet or T1
interface has been disconnected.
[off], on
This trap is sent when the Ethernet or T1
interface has been connected.
[off], on
This trap is sent after each login failure has
occurred.
[off], on
This submenu is for changing the T1 trap
settings.
Access online assistance
363-208-050
(Continued on next page)