Lucent Technologies SLC ConnectReach User & Service Manual page 288

Access system
Table of Contents

Advertisement

Installation
Connect Cables to the SLC ConnectReach System
Construct Cable Assemblies
T1, straight RJ-48
to RJ-48
5-36
Issue 4
June 2002
(Continued)
The following figure illustrates the assembly of the required cable to connect the
SLC ConnectReach system using the T1 RJ-48 to RJ-48 straight connection. The
transmit (TX) and receive (RX) designations are relative to the SLC
ConnectReach system.
NOTE:
Note the following assembly requirements.
TX-TIP and TX-RING must be the same twisted pair.
3
RX-TIP and RX-RING must be the same twisted pair.
3
Vendor PN, Siemans Co. MC5-S-8T-10-B02.
3
10-foot shielded.
3
363-208-050
(Continued on next page)