Provisioning the SLC
-2000 RT/HDT
Provision Channel Unit(s) at SLC
System
Using the CIT to Provision Channel
Unit(s) (Continued)
Once a CIT is connected to the UIP, you must log in to the digital loop carrier
Defining ENT-T0
(DLC) subsystem to execute the ED-T0 or ENT-T0 command. The ED-T0 or
and ED-T0
ENT-T0 CIT commands can be executed in two ways, "expert " or "prompted ".
commands
The expert, or command mode, syntax allows you to provision channel
(continued)
provisionable parameters (all or some) with a one-line command. All provisionable
parameters not entered in this one-line command retain their current values or are
initialized to the default values. The ED-T0 or ENT-T0 command is entered as
follows:
ED-T0:: address ::: clei,functioncode : param1=val1,param2=val2,... ;
ENT-T0:: address ::: clei,functioncode : param1=val1,param2=val2,... ;
where address is the channel address (AID),
clei and functioncode determine the channel function.
param=value are provisionable parameters for the particular channel unit
function selected, for example:
ED-T0::dtdp-1-1-1-1:::SAC1AE,fxs:imp=600,
bal=2,xmt(gn)=2,rcv(gn)=8.5,sl=2,rls=n;
As the name expert implies, this command syntax should be used with caution
only by experienced craft personnel. Refer to the ENT-T0 DLC subsystem
command in 363-208-003, SLC -2000 Access System, Commands and
Messages, for a list of the functional COMMON LANGUAGE
The steps in this procedure cover the prompted command entry method. The
prompted command entry method is started by entering only ED-T0 or ENT-T0 at
the prompt. A menu will prompt you to select a channel address. Subsequent
menus will prompt for COMMON LANGUAGE CLEI code, function code, and
provisioned parameter values. At any time you can enter "?" for help.
* Common Language is a registered trademark of Telcordia Technologies, Inc. CLLI, CLFI, CLCI, CLEI, NC/NCI,
Locatelt, and TeleHunt are trademarks of Telcordia Technologies, Inc. Functional COMMON LANGUAGE CLEI
codes are the first six characters/digits of the channel unit COMMON LANGUAGE CLEI code and are used in the
ED-T0 or ENT-T0 command.
®
ConnectReach
NOTE:
This procedure does not provide information to determine parameter
values. It assumes a work order record detail (WORD) or equivalent
document will provide all parameter values needed to provision the circuit.