Lucent Technologies SLC ConnectReach User & Service Manual page 76

Access system
Table of Contents

Advertisement

Preinstallation Planning
Configuration and Installation Process
Quickstart Configuration (Continued)
Quickstart
configuration
planning process
(continued)
3-6
Issue 4
June 2002
4.
Synchronous interface information:
— Encapsulation scheme used on the link to the CO (frame relay).
— SLC ConnectReach system IP address on the link to the CO.
— Netmask (if any) for that address.
— If frame relay, the data link connection identifier (DLCI) assigned to
the SLC ConnectReach system
— If frame relay, the local management interface (LMI) type used in
signaling.
5.
To configure the channel bank, you will need to know the CO digital trunk
configuration and the configuration of the equipment [analog phones,
private branch exchange (PBX), or key system] at the site [number 6
(Channel bank) on the worksheet]. The following is a list of provisionable
channel bank parameters:
— Trunk type (loop-ground)
— Analog interface (FXS-loop)
— Loop reversal from CO (enabled)
— Transmit gain (–3 db)
— Receive gain (–3 db)
— On-hook threshold (1250 milliseconds)
— Alarm state (busy)
— State of unconfigured channels (idle).