Lucent Technologies SLC ConnectReach User & Service Manual page 329

Access system
Table of Contents

Advertisement

®
Provisioning the SLC
-2000 RT/HDT
Provision Channel Unit(s) at SLC
System
Using the CIT to Provision Channel
Unit(s) (Continued)
SPQ 456 (DID, FXO-Loop, FXO-Ground, Current Sink)
Channel unit
provisioning
parameters
All four channels of the SPQ456 channel unit must be provisioned.
(continued)
Function code: RVT
CLEI: SACPDC
Provisioning parameters:
Entering RTRV-T0
Enter the RTRV-T0:dtdp-{1-8}-{1,3,5,7,9,11,13,15,17,19,21,23}-
{1-6}-{1-4} command for the channel address you plan to provision.
command
Using the information retrieved using the RTRV-T0 command, verify that this
circuit is actually the one that you want to provision. Contact your supervisor, if
necessary.
Entering the
provision data
®
ConnectReach
Provisioning Parameter
ls=Transmission loss
rls =Redlined
Step
Procedure
1
If necessary, perform the procedure presented earlier in this chapter in
the section entitled "CIT Set Up and Connection" to set up and connect
the CIT.
2
At the CIT prompt, enter the ENT-T0 command.
3
NOTE:
For help, type "?" for acceptable input parameters.
At the address= prompt, enter the channel access identifier address in
the syntax as determined previously.
WORD
Abbreviation
Value
LS
2.5 dB (default)
RLS
NO or YES (customer's choice)
363-208-050
(Continued on next page)
6-21
Issue 4
June 2002