The SLC ConnectReach system uses the standard request for comment (RFC)
1490 to send IP packets over a frame relay connection. The local management
interface (LMI)-type provides for two different signaling specifications, T1.617
(ANSI) and Q.933-annex-A [international telecommunication union/consultative
committee for international telegraph and telephone (ITU/CCITT)]. The frame
relay modification menu allows configuration for as many as 30 permanent virtual
circuits (PVCs). At the Config:Synchronous-interface prompt, enter the
Modify-encap-data command to access the frame relay commands listed in the
following table:
Enter this
command...
...and specify this value
PVC
(1...30)
none,[T1.617-annex-D
LMI-type
Q.933-annex-A
N391
[6] 1...255
N392
[3] 1...255
N393
[3] 1...10
T391
[6] 1...10
show-all-PVCs
Help
* This setting is sometimes referred to as Annex D or ANSI.
This setting is sometimes referred to as CCITT or ITU.
It is recommended that you use the default values for these commands unless the carrier specifies
otherwise.
Comments
Defines the specified PVC.
*
Specify annex type of Local
],
Management Interface (LMI).
Specify the polling cycles for status of
all permanent virtual circuits (PVCs).
Specify the threshold for the
monitored event counter.
Specify the monitored event counter
interval.
Specify the time in seconds for LMI
requests to be sent.
Displays the configuration for all
PVCs.
Access online assistance.
(Continued on next page)
Issue 4
363-208-050
June 2002
4-41