Installation
48-Line Master/Slave Configuration
Connecting Master and Slave Units
(Continued)
Procedure
(continued)
Step
Procedure
14
Refer to Chapter 4, "Configuring the SLC
set up a console session on the master SLC ConnectReach system.
The master SLC ConnectReach system must be configured to accept a
slave. This is done in the Config:Secondary/Fractional-t1 menu. The
has-slave command must be set on. For more information on this
menu, see Chapter 4, "Configuring the SLC
15
Follow the instructions in the ConnectReach Access System,
User/Service and Ordering Manual to set up a console session on the
slave ConnectReach system. The slave unit must be configured as a
slave.
16
At this point the SLC ConnectReach system and the ConnectReach
system are connected as master and slave. The voice channel details will
be configured on the master SLC ConnectReach system. The slave
ConnectReach system will reflect any changes made on the master SLC
ConnectReach system. For more information, refer to Chapter 4,
"Configuring the SLC
NOTE:
Systems configured for Master/Slave have the following limitation;
the total of combined Lines and Analog trunks are not to exceed 16
on the Master SLC ConnectReach system.
®
ConnectReach
®
®
ConnectReach
System".
363-208-050
System", to
ConnectReach
System".
Issue 4