Provisioning the SLC
-2000 RT/HDT
DS0 Cross-Connections
Establishing Cross-Connections from the
CIT (Continued)
Introduction
(continued)
Entering
ENT-CRS-T0
command
At the SLC-2000 HDT, the ENT-CRS-T0 command is also used to cross-connect
DS0s providing data services to an INA DS1 that interfaces with a data network
such as the Internet or a private corporate network through a frame relay network.
The only circuit card associated with the SLC ConnectReach system data
services is the SPQ452. The SPQ452 office channel unit (OCU) data port circuit
card is normally associated with the DS0 data channel bandwidth through the
Ethernet port. It usually provides data services but will also support some services
associated with the secondary/fractional T1/DSX-1 port.
The following procedure should be used to enter T0 cross-connects at the CIT.
Step
Procedure
1
If necessary, perform the procedure presented earlier in this chapter in
the section entitled "CIT Setup and Connection" to set up and connect the
CIT.
2
At the CIT prompt, enter the rtrv-crs-t0:: address command to
obtain a T0 cross-connect report showing the channel address
cross-connected together. Enter the dlt-crs-t0 to delete all T0
cross-connections for the channel unit slots being equipped.
3
Execute the ent-crs-t0:: address1,address2 command at the CIT for
the DS0 time slot to be cross-connected (for example,
ent-crs-t0::v3dp-1-5,dtdp-2-1-1-1 ). (Refer to document
363-208-003, SLC-2000 Access System, Commands and Messages for
additional information concerning CIT commands.)
4
Repeat Steps 2 and 3 for each DS0 time slot to be cross-connected.
5
Press DELete or CANcel key. Then enter logoff and disconnect the
CIT.
Stop! End of Procedure.
363-208-050
Issue 4
June 2002
6-13