Lucent Technologies SLC ConnectReach User & Service Manual page 423

Access system
Table of Contents

Advertisement

Software Upgrade, Maintenance, and Trouble Clearing
Maintenance Procedures
Upgrading the SLC ConnectReach System
with New Software (Continued)
Software upgrade
from the network
(continued)
Step
Procedure
5
Validate the password by entering it a second time at the prompt:
Validate password : support@lucent.com
6
To save the settings, enter the save command:
( Network-upgrade )> save
7
At the network-upgrade prompt, enter the prepare command:
(Network-upgrade)> prepare
8
The SLC ConnectReach system asks you to confirm that you want to
perform a warm restart and enter maintenance mode. Enter "y."
While the unit is in maintenance mode, data traffic from the local area
network (LAN) to the wide area network (WAN) and vice versa is blocked
in order to free enough memory to accommodate the download.
9
When the SLC ConnectReach system boots in maintenance mode, you
are prompted for your login name and password. Enter the carrier login
name and password.
10
At the Main Menu prompt, enter the network-upgrade command:
> network-upgrade
11
Execute the download:
(Network-upgrade)> download
Stop! End of Procedure.
363-208-050
(Continued on next page)
Issue 4
June 2002
9-9