Installation
®
Mount the SLC
ConnectReach
Mount the SLC
ConnectReach
®
System
Introduction
Three
configurations to
mount the unit
Clearances
System
The SLC ConnectReach system can be mounted in one of three configurations.
Rack mount (19- or 23-inch ANSI or Bellcore rack)
3
Wall mount (stationary or hinged bracket)
3
Desktop mount.
3
Mounting brackets that fit the 23-inch Bellcore racks with 25 mm hole spacing
(Comcode 108501362) may be ordered separately. A hinge mount kit (Comcode
108501354) is also available for ordering. The hinge mount, installed on a wall,
can hold up to four units mounted side-by-side on end. Thus providing space
saving capabilities. The hinged side allows the units to swing out for easier access
in servicing.
The following table lists the required clearances to install the SLC ConnectReach
system.
Area
Above unit
Below unit
Front of unit (near connectors)
Rear of unit
Sides of unit
Clearance (Inches)
1.75
0
5
0.6
2
Issue 4
June 2002
363-208-050
5-21