Lucent Technologies SLC ConnectReach User & Service Manual page 240

Access system
Table of Contents

Advertisement

®
Configuring the SLC
ConnectReach
Using the Configuration Commands
Configuring the RS-232 Interface
Procedure
4-154
Issue 4
June 2002
System
To configure the RS-232 interface, proceed as follows:
Step
Procedure
1
At the Config prompt, enter the RS232 command:
(config)> rs232
The prompt changes to the Config:RS232 prompt.
(config:RS232)>
At the Config:RS232 prompt, enter the baud-rate command and specify
2
the baud rate of the RS-232 port using the following table
Enter this command...
baud-rate
Help
3
When you have made the necessary configuration changes, you can
return to the Config menu by typing exit or an exclamation point (!)
(quoted as "\ |" through the SLC-2000 Access System CIT)
NOTE: The new command value takes effect as soon as you save the
configuration. You do not need to reboot the SLC ConnectReach
system to use the new value.
Stop! End of Procedure.
WARNING:
If you are using the RS-232 interface, and the settings are changed in the
RS232 menu and saved, the connection to the SLC ConnectReach system
will be disrupted. The interfacing software's baud rate must be changed to
match the baud rate set in the RS-232 configuration menu. The connection
will be restored when the software is restarted with the matching baud rate
setting.
...and specify the baud rate
[9600], 19200, 38400
(Continued on next page)
363-208-050
.