Lucent Technologies SLC ConnectReach User & Service Manual page 114

Access system
Table of Contents

Advertisement

®
Configuring the SLC
ConnectReach
Using the Configuration Commands
Configuring the Secondary/Fractional
T1/DSX-1 Interface (Continued)
Key commands
(continued)
4-28
Issue 4
June 2002
System
Line Buildout
T1 line buildout is configurable to 0 dB, –7.5 dB, or
–15 dB, as required by FCC Part 68. Buildout sets the
SLC ConnectReach system's output T1 transmission
signal level (0 dB is the highest level and -15 dB is the
lowest level). The default, 0 dB, is the most common
signal level for connection to the carrier. If line buildout
is set incorrectly, the carrier may detect errors ranging
from bipolar violations (line buildout too high) to loss of
signal (line buildout too low).
Pulse Density
Enforcement
This option is used when AMI line coding is selected
(see the description of line coding presented earlier).
Per the AT&T TR-62411 ACCUNET specification, bit
stuffing must be enabled when AMI line coding is
selected. This ensures that ones density requirements
are met (see ANSI standard T1.403, paragraph 5.6).
Alarm Operation
This option controls whether the secondary/fractional
T1/DSX-1 going down causes the alarm relay to close.
Refer to Chapter 9, "Software Upgrade, Maintenance,
and Trouble Clearing", for more information.
Alarm Delay
This option sets the delay between the
secondary/fractional T1/DSX-1 alarm and the closing
of the alarm relay.
Has Slave
This option allows the SLC ConnectReach system to
serve as the master unit in a 48-line master/slave
configuration. Refer to Chapter 5, "Installation" for
details on the 48-line master/slave configuration.
NOTE:
The clock source for the secondary/fractional T1/DSX-1 is always internal,
synchronous to the network T1/DSX-1.
363-208-050
(Continued on next page)