Software Upgrade, Maintenance, and Trouble Clearing
Maintenance Procedures
Upgrading the SLC
System with New Software (Continued)
Software upgrade
from a remote
computer
(continued)
Software upgrade
from the network
®
ConnectReach
Step
Procedure
9
Dial the modem connected to the SLC ConnectReach system again.
After the system has rebooted, verify that the system is running the new
software. Check the version number using the version command at the
Main Menu prompt or by viewing the version number that appears on the
screen after rebooting.
SLC ConnectReach System (x.xx)
Where x.xx is the software version.
Stop! End of Procedure.
NOTE:
The procedures to upgrade the SLC ConnectReach system software from
the network are for future use only since the Lucent Technologies network
upgrade server site is presently unavailable.
There are two procedures for upgrading the SLC ConnectReach system software
from the network — normal upgrade and custom upgrade. Both procedures are
identical with one exception, the normal upgrade procedure uses default (user
supplied) values already in the system for the network upgrade commands
whereas, the custom upgrade procedure requires that these network command
values be specified.
The software to be downloaded is stored at the FTP server in a file named
lucent.st_rom.xxx, where the suffix xxx is the version string you must enter with
the version command. The FTP server may be case-sensitive, so be sure to
enter any alphabetic characters exactly as they appear in the file suffix.
363-208-050