Provisioning the SLC
-2000 RT/HDT
CIT Setup and Connection

Set Up CIT

Procedure
Use the following procedure to set the terminal parameters of the CIT and select
the appropriate subsystem in preparation to enter commands:
Step
Procedure
1
Turn on the CIT and set the terminal parameters as follows (consult your
terminal's manual for setup procedures):
Full duplex
3
8 data bits
3
1 start bit
3
1 stop bit
3
No flow control
3
Baud rate set the same as the SET-BAUD UIP command.
3
NOTE:
If using a PC as a CIT terminal, run the CTRM terminal emulator
software.
2
Enter a question mark (?) or RETURN. The CIT prompts with:
/* Enter 1 to continue */
subsystem =
3
Enter 1 .
4
The CIT will respond with " login <" (enter LUC01 , LUC02 , or LUC03 )
and " password " (enter SLC-2000 ).
Response: The CIT will display a SONET alarm summary generated by
the rtrv-alm: all command. The CIT will then display a prompt. To
move to the DLC subsystem side, enter dlc .
5
You are ready to enter commands. Refer to document 363-208-003,
SLC-2000 Access System, Commands and Messages, for available
commands. To end a CIT session, enter logout and disconnect the CIT.
Stop! End of Procedure.
363-208-050
Issue 4
June 2002
6-5