SLC ConnectReach System Monitoring
Using the Statistics Command to Display System
Elements Status
Displaying Statistics for a T1 Interface
(Continued)
Displaying status on
a T1 line
(continued)
If "NO" is displayed after any of the conditions in the status report, this is an
indication that no error is detected by the SLC ConnectReach system. If "Yes" is
displayed, this is an indication that the corresponding error condition has been
detected.
T1 line error conditions and the corresponding corrective actions are listed in the
following table.
Condition
Corrective Action
A problem with the wiring exists. Check the physical connection.
Loss of Signal
Contact the carrier if necessary.
The most recent 10 or more seconds have been flagged Errored
Unavailable State
Seconds. A problem with the T1 line exists. Contact the carrier.
The line is configured for the wrong framing format. Verify with the
Loss of Frame
carrier whether the framing format should be changed.
Alarm Indication Signal (AIS). Loop has been placed down at the
Receive AIS
remote end. Contact the carrier.
Remote Alarm Indicator (RAI). This indicates an error at the remote
Receive RAI
end. Contact the carrier.
Transmit RAI
Errors in these categories usually indicate that the T1 line is
incorrectly configured. Check that the SLC ConnectReach system
Transmit AIS
configuration matches the carrier's configuration of the line.