Software Upgrade, Maintenance, and Trouble Clearing
Maintenance Procedures
Upgrading the SLC
System with New Software (Continued)
Software upgrade
from a local
computer
(continued)
9-4
Issue 4
June 2002
®
ConnectReach
Step
Procedure
4
The SLC ConnectReach system will ask for confirmation that you want to
perform a warm restart and enter the maintenance mode. Enter "y."
NOTE:
While the unit is in the maintenance mode, data traffic from the
LAN to the WAN and vice versa are blocked in order to free
enough memory to accommodate the download.
5
When the SLC ConnectReach system boots in the maintenance mode,
you are prompted for your login name and password. Enter the carrier
login name and password.
6
At the Main menu prompt, enter the xmodem-download command.
> xmodem-download
The system responds with:
1 meg of ram allocated for preparing flash
followed by: CCCCCC
While the CCCCCC string is progressing across the screen, start a file
transfer using the terminal emulator
7
From the terminal application, send the file using the xmodem protocol.
In Hyperterminal, a Windows application, select Transfer from the menu
bar and select Send File. When the Send File dialog box appears, select
the Xmodem protocol and enter the path and file name. If binary or
American standard code for information interchange (ASCII) is an option,
choose binary.
363-208-050
(Continued on next page)