Lucent Technologies SLC ConnectReach User & Service Manual page 111

Access system
Table of Contents

Advertisement

®
Configuring the SLC
ConnectReach
Using the Configuration Commands
Configuring the Network T1/DSX-1
Interface (Continued)
Procedure
(continued
System
Step
Procedure
2
cont.
To
Enable Network T1/DSX-1
Set the framing format
Set the line coding format
Set the build out in feet or decibels
Set the clock source (this option only
available if internal clock exists)
Comply with ones density specification
(applies only to AMI line coding)
If set to on, an alarm on Network T1/
DSX-1 will cause the alarm relay to close
Sets the delay between a Network T1/
DSX-1 alarm and closing of the alarm
relay
®
Set the SLC
ConnectReach
as a slave to another SLC
ConnectReach system (allows for 25-48
ports for voice only)
Sets the number of bipolar violations
allowed and shelf emulation
Access online assistance
*
This command is not available on systems with software R5.0.1 and later.
The line buildout command may be specified for connection to a channel service unit (CSU) or to a
digital signal cross-connect (DSX). For a CSU, the value is specified in decibels (dB); for a DSX, the
value is specified in feet.
All of the channel units for the DS0-Provisioning:ConnectReach command must also be set to none
to allow for a slave.
§
This command is not used and not available on systems with software R5.0.1 and later.
Enter this
command...
enable
framing
linecode
buildout
clock
pulse-
density-
enforce
alarm-
operation
alarm-
delay
system
is-slave
Modify-
tr08-data
Help
363-208-050
...and one of these
options
off, [on]
*
[ESF], D4, TR08
[B8ZS], AMI
[0-133ft(DSX)/
0dB(CSU)],
133-266ft(DSX),
266-399ft(DSX),
399-533ft(DSX),
533-655ft(DSX),
–7.5dB(CSU),
–15dB(CSU),
-22.5dB(CSU)
[network],
internal
[off], on
off, [on]
0..[15]..3600 sec
[off], on
§
Issue 4
June 2002
4-25

Advertisement

Table of Contents
loading

Table of Contents