Provision Channel Unit(S) At Slc Connectreach System; Using The Cit To Provision Channel Unit(S) - Lucent Technologies SLC ConnectReach User & Service Manual

Access system
Table of Contents

Advertisement

®
Provisioning the SLC
-2000 RT/HDT
Provision Channel Unit(s) at SLC
System
Provision Channel Unit(s) at SLC
ConnectReach
Using the CIT to Provision Channel
Unit(s)
This procedure uses a craft interface terminal (CIT) at the SLC -2000 remote
Overview
terminal/host digital terminal (RT/HDT) to set provisioning parameters on the
channel units located at the SLC ConnectReach system.
Defining ENT-T0
The SLC ConnectReach system channel units [SPQ
SPQ452, or SPQ456] can be provisioned using either the ENT-T0 or ED-T0
and ED-T0
command specifying the access identifier (AID) address of the channel unit. The
commands
provisioning data that is stored in memory is used by the channel unit to
determine what circuit function to provide and what parameter values to use. The
RTRV-T0 command can be used to review the provisioning parameters for a
channel. You should use the RTRV-T0 command to verify the drop address before
setting provisioning information. Verifying provisioning will not change an
in-service circuit.
The ENT-T0 and ED-T0 commands use channel addresses in the form of:
dtdp- {metallic distribution shelf number}-{DT Server slot}- {DT channel unit slot
number}-{DS0 of the channel unit}
Where "DT Server slot" is the MDS channel unit slot number where the DT Server
is installed.
The use of the ED-T0 or ENT-T0 command is possible by means of remote
provisioning where a CIT is connected to the user interface panel (UIP) CIT jack
at the remote terminal (RT).
6-14
Issue 4
June 2002
®
ConnectReach
®
System
363-208-050
®
440(C,D), SPQ443,
(Continued on next page)