Configuring the SLC
ConnectReach
Using the Configuration Commands
Configuring the Synchronous Interface
(Continued)
Configuring using
the PVC submenu
commands
(continued)
4-46
Issue 4
June 2002
System
2
Cont.
Enter this
command...
PVCDownThreshold [0]...100
Help
The statistics described in the following table will be measured when SLA is
enabled on a PVC.
Statistic
End-to-End Latency Once a minute
Peak End-to-End
latency
Data Delivery
Ratio Above CIR
...and specify this
value
Comments
This is an SNMP trap parameter.
This trap is sent when the PVC
down time exceeds the defined
threshold. The number represents
the number of times the PVC has
been down within the 15 minute
interval.
Access online assistance.
Sampling
Interval
Description
This is a running average of the
current 15 minute interval. These
units are in milliseconds.
This is the peak latency so far during
the current 15 minute interval. These
units are in milliseconds.
Once a minute
A ratio of the number of bytes
received over the number of bytes
sent that are above the CIR. This is a
percent value with units of measure
as low as 1/100 of a percent.
Once a minute