Rack Mount - Lucent Technologies SLC ConnectReach User & Service Manual

Access system
Table of Contents

Advertisement

Installation
®
Mount the SLC
ConnectReach

Rack Mount

Mount the SLC
ConnectReach
system in a 19-inch
rack
5-22
Issue 4
June 2002
System
NOTE:
The mounting brackets supplied with the SLC ConnectReach system are
for mounting the unit in an American national standards institute (ANSI)
type relay rack. The mounting brackets required to mount the unit in a
Bellcore relay rack must be ordered separately. Refer to document
363-208-000, SLC-2000 Access System, Applications, Planning, and
Ordering Guide, for ordering information.
To mount the SLC ConnectReach system in a 19-inch rack, attach the long side of
the brackets to the SLC ConnectReach system as shown in the following
illustrations. You can arrange the brackets for a front, midway, or rear mount.
NOTE:
Attach the long side of the brackets to the SLC ConnectReach system.
Front mount
Install the brackets as shown to front mount the SLC ConnectReach System in a
19-inch rack.
Midway mount (preferred)
Install the brackets as shown to midway mount the SLC ConnectReach System in
a 19-inch rack.
363-208-050
(Continued on next page)