Lucent Technologies SLC ConnectReach User & Service Manual page 122

Access system
Table of Contents

Advertisement

®
Configuring the SLC
ConnectReach
Using the Configuration Commands
Configuring DS0 Provisioning
(Continued)
Examples of
channel assignment
schemes
4-36
Issue 4
June 2002
System
Examples of channel assignment schemes are listed below:
Configure full T1 bandwidth for data as follows: set data-begin to 1,
3
data-end to 24, and all other values to 0 (zero).
Configure full T1 bandwidth for voice lines connected to the
3
Secondary/Fractional T1/DSX-1 connector as follows: set
sec/frac-t1-voice-begin to 1, sec/frac-t1-voice-end to 24, and all other
values to 0 (zero).
Configure half the T1 bandwidth for analog voice connections and
3
half for data as follows: set analog-begin to 1, analog-end to 12, data-
begin to 13, and data-end to 24.
NOTE:
There is a restriction in the same mode, that any DS0s used for analog
voice must have lower channel numbers than any DS0s used for the
Secondary/Fractional T1/DSX-1.
It is recommended that you always configure the voice channel range to start with
the lowest numbered channel group (1—4) and increment from there. Configure
the data channel range to start with the highest numbered channel group
(21—24) and decrement from there. If some channels are unconfigured, it will be
easier to make changes later if the unconfigured channels are between the voice
range and the data range.
363-208-050
(Continued on next page)