Configuring the SLC
ConnectReach
Using the Configuration Commands
Configuring the Synchronous Interface
(Continued)
Procedure
4-40
Issue 4
June 2002
System
Step
Procedure
At the Config prompt, enter the synchronous-interface command:
1
(config)>
synchronous-interface
The prompt changes to the Config:Synchronous-interface prompt.
(config:Synchronous-interface)>
To set the synchronous interface encapsulation, enter the encapsulation
2
command at the Config:Synchronous-interface prompt and the
appropriate setting from the following table.
Enter this command...
encapsulation
HDLC-inversion
modify-encap-data
Help
Enter the Modify-encap-data command to specify values appropriate to
3
the chosen encapsulation scheme. The Modify-encap-data command
changes the prompt to the selected encapsulation scheme.
(config:Frame-relay)>
or
(config:PPP)>
or
(config:HDLC)>
Refer to one of the following procedures that pertains to the selected
encapsulation scheme to complete the configuration.
4
When you have made the necessary configuration changes, you can
return to the Config menu by typing exit or an exclamation point (!)
(quoted as "\ |" through the SLC-2000 Access System CIT).
NOTE: If you change any of these commands, except IP addressing,
you must save the configuration and reboot the SLC ConnectReach
system using the warm-start command for the new settings to take
effect. IP addressing takes effect when the save command is executed.
Stop! End of Procedure.