Lucent Technologies SLC ConnectReach User & Service Manual page 331

Access system
Table of Contents

Advertisement

®
Provisioning the SLC
-2000 RT/HDT
Provision Channel Unit(s) at SLC
System
Using the CIT to Provision Channel
Unit(s) (Continued)
Entering the
provision data
(continued)
®
ConnectReach
Step
Procedure
7
After all parameters have been entered, you will see a confirmation or
error message preceded by one or more caution messages.
The channel provisioning settings will be listed. Then the following will
appear:
Execute? (y/n or CANcel/DELete to quit) =
If you enter "y", the provisioning data just entered will be applied. If you
enter "n", you will be brought back to the ENT-T0 address= prompt and
the provisioning data just entered will be ignored. If you press "CANcel/
DELete" keys, you will be dropped out of the ENT-T0 command back to
the system prompt and the provisioning data just entered will be ignored.
If the channel slot cannot be provisioned as requested (for example,
because of channel unit limitations), the following message will be
displayed. Report this trouble to your supervisor.
IDNV /* Input, data not valid
Cannot support CLEI code XXXXXX for line address */
XXXXXX is the functional CLEI code entered, and address is the metallic
distribution shelf and channel number selected.
8
Enter " y" to provision the channel.
Stop! End of Procedure.
363-208-050
6-23
Issue 4
June 2002