Configuring the SLC
ConnectReach
Using the Configuration Commands
Configuring SYSLOG (Continued)
Procedure
(continued)
System
Step
Procedure
2
Make the necessary syslog configuration changes. The following table
describes the configuration commands
Enter this
command
...and specify this value Comments
enable
[off], on
host
IP address
source
source ID string
sysconf
facility
access
facility
Help
Enables or disables the syslog utility.
Syslog can only be enabled if you have
specified a valid host name.
Specifies the IP address of the device
to which you want the syslog messages
sent.
Specifies device from which messages
are sent; enter IP address or user-
defined string to identify device;
appears as 'hostname' element of each
syslog message.
Limits syslog reports to facility code 1
(user-level) messages generated due to
configuration events.
Limits syslog reports to facility code 4
(Security/Authorization) messages
generated due to user access events.
Access online assistance.