Lucent Technologies SLC ConnectReach User & Service Manual page 115

Access system
Table of Contents

Advertisement

®
Configuring the SLC
ConnectReach
Using the Configuration Commands
Configuring the Secondary/Fractional
T1/DSX-1 Interface (Continued)
Procedure
System
After you have verified the required configuration, follow these steps to configure
the secondary/fractional T1/DSX-1 interface for the SLC ConnectReach system:
Step
Procedure
1
At the Config prompt, enter the secondary-t1 (T1/DSX-1 interface)
command:
secondary-t1 or
(config)>
The prompt changes to the Config:Secondary T1 or Config:Fractional T1
prompt.
(config:Secondary-t1)> or (config:Fractional-t1)>
(config)>
fractional-t1
(Continued on next page)
Issue 4
363-208-050
June 2002
4-29