Lucent Technologies SLC ConnectReach User & Service Manual page 319

Access system
Table of Contents

Advertisement

®
Provisioning the SLC
-2000 RT/HDT
DT Server Preparation, Installation, and Provisioning
Provision DT Server from CIT
(Continued)
Procedure
(continued)
Step
Procedure
2
At the CIT prompt, enter the rtrv-dt command to review the time slot
allocation of the DT Server serving the SLC ConnectReach system.
Response: The CIT will print a message indicating the Lines Provisioned
Value, DT Mode, DT Type, DT Address, Available
Bandwidth, and CLEI Code for the DT Server slot whose AID
you entered.
3
If the following parameters do not agree with the parameters displayed on
the CIT, proceed to Step 4. Otherwise, press the DELete or CANcel key,
enter logoff , and disconnect the CIT (DT Server parameters are
already set correctly).
dttype=crdt
3
dtmode=quad
3
lines= 12 or 24.
3
4
At the CIT prompt, press the DELete or CANcel key and enter the ed-dt
command.
5
At the address= prompt, enter the DT Server AID determined
previously.
6
At the dttype= prompt, enter crdt.
7
At the lines= prompt, enter 12 or 24.
8
At the dtmode= prompt, enter quad.
9
After all parameters have been entered, you will see a confirmation
message preceded by a caution message.
The parameter settings will be listed. Then the following will appear.
Execute? (y/n or CANcel/DELete to quit) =
If you enter "y", the provisioning data just entered will be applied. If you
enter "n", you will be brought back to the ED-DT address= prompt and
the provisioning data just entered will be ignored. If you press the
"CANcel/DELete" key, you will be dropped out of the ED-DT command
back to the system prompt and the provisioning data just entered will be
ignored.
10
Enter " y" to provision the DT Server slot.
Stop! End of Procedure.
363-208-050
Issue 4
June 2002