Lucent Technologies SLC ConnectReach User & Service Manual page 263

Access system
Table of Contents

Advertisement

Installation
Interface Card Installation
Voice Interface Card Installation
(Continued)
Procedure
The following procedure should be used when installing FXS and/or FXO voice
interface cards in the SLC ConnectReach system.
NOTE:
If Voice Interface Slots 2 and/or 3 are to be equipped with a voice interface
card, then Voice Interface Slot 1 must also be equipped. If Slot 1 is not
equipped, then the cards in Slot 2 and/or 3 will not be recognized.
Step
Procedure
1
Verify that power has been removed from the SLC ConnectReach system
unit.
2
An electrostatic discharge (ESD) wrist strap with a resistance between
250 K and 1.5 M ohms should be worn when handling the SLC
ConnectReach system interface cards or motherboard to prevent
damage. Before using the wrist strap, check it for shorts, opens, and
proper resistance value. If the strap does not pass these checks, it should
not be used. To avoid possible personal injury while using the wrist strap,
do not connect it to any power source or shelf housing a power source.
Use a Phillips screwdriver to remove the screw from the center of the SLC
ConnectReach system front panel.
3
Obtain access to the inside of the SLC ConnectReach system by sliding
the bottom tray/front panel assembly forward, separating it from the top
and side cover.
363-208-050
(Continued on next page)
Issue 4
June 2002
5-11