Lucent Technologies SLC ConnectReach User & Service Manual page 142

Access system
Table of Contents

Advertisement

®
Configuring the SLC
ConnectReach
Using the Configuration Commands
Configuring the Channel Bank Mode
(Continued)
Key commands
(continued)
4-56
Issue 4
June 2002
System
On-hook-
This command (expressed in milliseconds) allows
threshold
the
between a flash request and an on-hook
(disconnect) condition. If the telephone equipment
on the far end of the digital trunk supports hook
switch flash, set
enough interval (1500 milliseconds is typical) for the
SLC ConnectReach
a flash and a disconnect. Note that during the
hook-threshold interval, the on-hook is sent to
the far end equipment. If the telephone equipment
does not support flash, use the default value of
1250 milliseconds.
Alarm-state
In the event of a network T1 alarm, this command
determines if the FXS is to be put into a tip closed
(battery supplied) or tip open (no battery supplied)
state. If this command is set to busy, then battery will
be supplied. If set to idle, then no battery will be
supplied.
Unconfigured-
This command determines if the FXS ports for
state
unconfigured channels are put into a
(battery supplied) or tip open (no battery supplied)
state. If this command is set to busy, then battery will
be supplied. If set to idle, then no battery will be
supplied. It is not part of the configuration template
and has no impact on configured channels.
Load template
This command loads all of the configuration command
values that are stored in a template to the channel
being configured. This command allows multiple
channels to be set up identically without having to
enter each individual command for all channels.
Cross-connect
This command allows assignment of DS0s to specific
lines. This becomes relevant when using four port
boards or a combination of FXS and FXO boards with
less than eight lines used on each board. If this
command is enabled, then all DS0s must be assigned
through the associated submenu.
SLC ConnectReach
system to differentiate
on-hook-threshold to a long
system to differentiate between
363-208-050
on-
tip closed