Lucent Technologies SLC ConnectReach User & Service Manual page 107

Access system
Table of Contents

Advertisement

®
Configuring the SLC
ConnectReach
Using the Configuration Commands
Basic Procedure For Using the
Configuration Commands (Continued)
Activating new
configuration
settings (continued)
Archiving
configuration
settings
System
NOTE:
Using the warm-start command to reboot a SLC ConnectReach system
providing TR-08 service and feeding a SLC-2000 HDT interrupts all existing
data connections for up to 60 seconds. Existing voice connections may
have their speech path interrupted for up to one tenth of a second during
the restart process. The calls will not be disconnected, but new
connections cannot be made for up to 60 seconds. Using the warm-start
command to rebooting a SLC ConnectReach system providing TR-303
service drops all existing calls.
Rebooting the SLC ConnectReach system with the cold-start
command interrupts both voice and data connections. All connections are
lost. New connections cannot be made for up to 60 seconds.
If you set up login names during the initial configuration, when the SLC
ConnectReach system reboots, the Utility prompts you to enter a login name and
password. Information about login names is presented later in this chapter.
CAUTION:
Do not press any keys on the keyboard during the reboot process. If a key
has been pressed during a one second checking interval while the SLC
ConnectReach system is rebooting, the SLC ConnectReach system will
boot into the Monitor mode. The Monitor mode allows the RS-232 and
10Base-T ports to be operational. To exit the Monitor mode, restart the SLC
ConnectReach system and do not press any keys during the reboot
process.
In the event that the SLC ConnectReach system loses the configuration settings
stored in nonvolatile random access memory (NVRAM), it is suggested that the
configuration information be stored (archived) in a remote computer so that the
information can be restored without having to enter all of it again.
The archive command, located in the Main Menu, is used to upload the
configuration settings to a remote computer and download the saved
configuration settings from the remote computer. The archive command also
allows you to download identical or nearly identical settings to multiple SLC
ConnectReach system units from a remote computer.
For more information concerning the use of the archive command to upload and
download configuration settings from a remote computer, refer to Chapter 9,
"Software Upgrade, Maintenance, and Trouble Clearing".
363-208-050
Issue 4
June 2002
4-21

Advertisement

Table of Contents
loading