Provisioning the SLC
-2000 RT/HDT
CIT Setup and Connection
Connect CIT and Set Baud Rate at UIP
(Continued)
Procedure
(continued)
6-4
Issue 4
June 2002
Step
Procedure
2
Press the cover of the UIP to gain access to the CIT port. Connect CIT
terminal to CIT port by connecting one end of an RS-232 cable to the
COM1 port of the CIT (use a 9-pin to 25-pin converter, if necessary) and
the other end of the cable to the UIP CIT port (see the following figure).
3
Press the UIP Escape button and then the Scroll Menu down arrow
button until SET-BAUD: <ent> is displayed. Press the UIP Enter button
then the Scroll Menu down arrow button until the desired baud rate is
displayed (9,600 is the default for the terminal emulator software,
SYSCTL, and UIP). Press Enter to set the CIT baud rate.
Stop! End of Procedure.
363-208-050